S&P Product - Trail
S&P G-Sheet E 90/10 B - S&P G-Sheet AR 90/10 B
For increased uni-directional loads
JOSN
Product Information
S&P G-Sheet 90/10 is a bidirectional glass fibre fabric with high strength for structural reinforcement. It can be applied in a dry or wet lay-up process. S&P G-Sheets are applied (stuck-on) to the building element in question using laminating resin (S&P Resin 55 HP or S&P Resicem HP).
Features and Applications
Feature
- Flexible application, even on curved surfaces such as pillars, columns, silos, chimneys, walls, arched slabs, etc.
- Low self-weight and small installation thickness
- Easy, flexible, and economical strengthening method
- No corrosion
- Very short interruption in the normal use of the building
- No noise and no vibration during installation
Applications
- Strengthening or reinforcement of bearing structures made from reinforced concrete and masonry, against flexural (bending tensile) and axial stresses
- Increasing strength and ductility of columns and walls
- Increasing resistance to an earthquake
- Increasing imposed loads
- Replacement of corroded or missing reinforcement
- In case of a change in the nature of imposed loads
- Correction of design and/or building mistakes
- Extension of service life and durability
- Complying with the latest standards
Technical Data
Logistic Data
Logistical Data
Delivery | S&P G-Sheet E 90/10 B (880 g/m²) | S&P G-Sheet AR 90/10 B (880 g/m²) |
---|---|---|
Widht of roll: | 670 mm | 670 mm |
Length of roll: | 50 m | 50 m |
(special sheets upon request) |
Storage |
---|
Storage temperature between +5 °C and +35 °C. Store in a dry place and protect from direct sunlight. |
Item number | Article | ||
---|---|---|---|
GSE09010B67 | S&P G-Sheet E 90/10 Typ B | ||
GSAR9010B67 | S&P G-Sheet AR 90/10 Typ B |
Safety Data
Safety Data
For detailed safety information it is recommended to seek advice in the current safety data sheet.
Installation Instructions
Installation Instructions
Cut sheets with scissors or knife and ruler. Never bend the sheets! (Sheet may only be folded parallel to the fibre). The S&P G-Sheet can be applied in a dry or wet lay-up process.
For details please refer to the application manual for S&P G-Sheet E/AR.