S&P Asphalt reinforcement
Fibre reinforcement grids for asphalt surfaces
Flexural
One of the bridge's edge beams had been hit and the damage had caused major damage, destroying parts of the concrete and 7 pre-stressed cables.
Re-establishing pre-tensioned cables would be an expensive and time-consuming solution that would cause major traffic challenges on the busy motorway under the bridge.
The bridge's edge beam was restored to its original profile by a concrete repair and then the reinforcement was established with embedded carbon fibre rods (S&P C-Rod), which were placed in a milled groove filled with glue (Near Surface Mounted solution). The 7 pre-stressed cables could be replaced with just 4 carbon fibre rods ø8mm. At one end at the centre of the concrete beam, carbon fibre sheet (S&P C-Sheet) was secured as a U-shaped enclosure. The work was carried out overnight and in a very short time, causing only minor disruption to traffic.
S&P C-Rod ø8mm, S&P Resin 220 HP, S&P C-Sheet, S&P Resin 55 HP
Denmark
Hedegaardsvej 11
DK-8300 Odder
CVR 65653818