Earthquake reinforcement of masonry - CS Division Office - Glarus, Switzerland

On this page

Topic
Earthquake reinforcement of masonry
Object
CS Division Office
Location
Glarus/GL
City
Glarus
State
Glarus
Country
Switzerland
Date
Duration
4 Months

S&P Case Study

Solution

As part of a total renovation regarding earthquake resistance, this protected monument has been reinforced to meet norms. The statics calculations showed that various masonry walls need to be reinforced over several storeys. Vertically prestressed S&P CFK-Laminates transfer dynamic earthquake loads into the foundations. Diagonal CFK laminates transfer horizontal loads in the new slabs through a “gusset plate”. The G-Sheet AR 50/50, installed in advance, reinforces the old stone masonry and holds it together. The epoxy resin S&P Recisem is used to ensure vapour diffusion.

Material

approx. 340 metres S&P CFK-Laminates and 200 m2 S&P G-Sheet AR 50/50