S&P Asphalt reinforcement
Fibre reinforcement grids for asphalt surfaces
Axial
The planned extension of residential building and department store Laubenhof in Zug required the reinforcement of 34 columns in two parking floors.
The pre-fabricated hollow-core columns were injected with high-strength shrinkage-free cement mortar beforehand. Different additional loads will be transferred by wrapping the columns in carbon fibre mesh (horizontal and vertical), as statically required. The concrete surface is prepared by grinding, onto which the S&P C-sheets are then applied using the vapour-permeable S&P Resicem, ensuring a multi-layered load-transferring connection. The structure is braced throughout the application period. For mechanical protection, the sheets are covered in a ca. 15mm thick protection mortar.
215 m2 S&P C-Sheet 240, 400 g/m2, 300 and 600 mm wide rolls