Solution 

The concrete columns in the warehouse storey need to be protected against impact damage. This must cover load combinations that include vehicles of up to 3.5 tons and forklift trucks. The static calculations show that the bottom 1.5 metres of the columns must be wrapped in a layer of S&P A-Sheet 120. The reinforcement mesh, made from aramid fibres (E-modulus 120 kN/mm2), is stuck onto the prepared substrate with the vapour-permeable epoxy resin S&P Resicem, forming a load-transferring adhesive bond.

Material 

per column, 8 m2 S&P A-Sheet 120, width of roll 300 mm

Marking the application surface / chamfering the edges

Grinding the substrate and re-profiling th edges with S&P Repcem

Priming with S&P Resicem (vapour permeable) and applying the S&P A-Sheets

Demonstration column showing the individual reinforcement work steps