Links: Mobile Menu v1

Languages

Block of flats - Pilgerstrasse - Baden, Switzerland

Seismic

Country 

Switzerland

Location 

Baden/AG (CH)

Date 

2013

Duration 

4 Months

Case Study 

Seismic retrofitting of masonry with S&P CFK-Laminates and S&P G-Sheets (FRP 2013_05)

Situation 

In the course of a total renovation, the roughly 50-year-old multi-family block of flats is to be reinforced to improve earthquake safety according to norms and requirements. The static calculations show that various masonry walls must be reinforced across several storeys. S&P CFK-Laminates will be used to transfer the dynamic loads into the foundations. The G-Sheets AR 50/50, applied beforehand, strengthen the horizontal joints in the masonry and hold these together. To meet vapour diffusion requirements, S&P Resicem is chosen for application.

Material 

approx. 700 metres of S&P CFK-Laminates and 500 m2 S&P G-Sheet AR 50/50

Preparing the application surface with grinding and re-profiling (S&P Repcem)

Reinforcing the masonry with S&P G-Sheet and S&P Resicem (vapour permeable)

Application and anchoring of the laminates as specified by the statics calculation

Completed reinforced masonry walls before finishing tasks